9
DIL switch settings – TPI temperature control software
Thermostats using TPI (Time Proportional Integral) control algorithms will reduce the temperature
swing that normally occurs when using traditional bellows or thermally operated thermostats.
As a consequence, a TPI regulating thermostat will maintain the comfort level far more efficiently
than any traditional thermostat.
When used with a condensing boiler, the TPI thermostat will help to save energy as the control
algorithm allows the boiler to operate in condensing mode more
consistently compared to older types of thermostat.
• DIL switch numbers 7 and 8 should be set as diagram opposite.
• For Gas boilers set the TPI setting to 6 cycles per hour.
(Default setting)
• For Oil boilers set the TPI setting to 3 cycles per hour.
• For Electric heating set the TPI setting to 12 cycles per hour.
Switch positions for
different TPI settings.